User manual

16
2. Ports 9~10: link failure (e.g.: cable disconnected,
device breakdown, etc.)
Note: The alarm function is disabled when the
SFP fiber module is absent.
3. PWR/RPS: Power failure
a. Power cord is disconnected, power
supply malfunction, etc.
b. Input power is out of the range listed in
the spec (9 ~ 48V)
DIP Switch Settings
DIP-switches allow for the user to manually turn ON/OFF
any port, the external Alarm, or the redundant power
supply. The figure below shows the DIP-switch control.
DIP 1
(PWR) Controls the primary power
external alarm input. Default is ON.
DIP 2 (RPS) controls the redundant power
external alarm input. Default is ON.
DIP 3-12 represents the alarm for port
numbers of the INS-802 Switch respectively.
Move the DIP switch to the ON position to
manually enable the alarm function. Default is
O
FF
.