2.3.- There after, place the unit between the projector and the projection window.
2.4.- manually operate the switch to raise the window of the SmartCrystal™ Cinema Polarizer Module in order to check it is raised to the
correct position.
Height
Adjustment
Height
Adjustment
Angle
Adjustment
+
X
Installation
The SmartCrystal™ Cinema should be placed directly in-front of the lens of the projector at a distance such that the image from the projector
covers as much as possible the entire area of the polarization window in order to minimize thermal heating effects.
Ensure that the side of the SmartCrystal™ Cinema marked “PROJECTOR SIDE” is facing towards the projector.
The SmartCrystal™ Cinema Polarizer Module should not be placed closer than 80mm from the projector lens.
The system starts as soon as it is connected to a power source.
80mm
FORBIDDEN AREA
SmartCrystal™ Cinema
positionning area
Projector
Not optimized Optimized Out of limits
A distance more than 80mm is normally
recommended for this purpose.
Set the SmartCrystal
TM
polarization panel at a slight incline to avoid scattering light
reection onto the projector lens and to reduce potential ghosting.
Monitor the distance between the projector and the SmartCrystal
TM
Cinema is very important to preserve the LCD.
The image must cover as much as possible of the LCD to avoid heating only a small part of the LCD.
OptimizedNot optimized