4.10 CASING REMOVAL
Lower the front control panel as described in
section 4.9.1.
● Locate and remove the 2 screws that secure
the controls fascia to the appliance casing (fig.
13A)
● locate and remove the 2 screws that secure the
casing to the back frame of the boiler (fig. 15)
● gently pull one side of the casing then the other
to disengage it from the retaining clips
● lift the casing upward to disengage it from the
top locating hooks and then remove
● store the casing and screws safely until required.
Re-fit in the reverse order.
screw
screw