Technical data
11
adaptor and insert the concentric flue pipe into
the flue bend ensuring the correct seal is made.
Using the clamp, gasket and screws supplied,
secure the flue bend to the appliance flue spigot.
NOTE
You must ensure that the entire flue system is
properly supported and connected.
Seal the flue assembly to the wall using cement
or a suitable alternative that will provide
satisfactory weatherproofing. The interior and
exterior trim can now be fitted.
4.5.1.1 EXTENDING THE FLUE
Connect the bend – supplied with the terminal kit
– to the top of the boiler using the boiler top
adapter and clamp (supplied, fig. 7). The additional
bends & extensions have push-fit connections,
care should be taken to ensure that the correct
seal is made when assembling the flue system.
Connect the required number of flue extensions
or bends (up to the maximum equivalent flue
length) to the flue terminal (fig. 7 & 7B).
Fig. 7A
NOTE
When cutting an extension to the required length,
you must ensure that the excess is cut from the
plain end of the extension (fig. 7 & 7B). Remove
any burrs, and check that all seals are located
properly.
You must ensure that the entire flue system is
properly supported and connected.
Seal the flue assembly to the wall using cement
or a suitable alternative that will provide
satisfactory weatherproofing. The interior and
exterior trim can now be fitted.
4.5.2 CONCENTRIC VERTICAL FLUE
The vertical flue terminal can be connected directly
to the appliance flue outlet. Alternatively, an
extension or bend can be connected to the
appliance flue outlet if desired (see section 2.9),
however if additional bends are fitted, a reduction
must be made to the maximum flue length (see
table below).
Reduction for bends
Bend
Reduction in maximum flue length for each bend
45° bend
90° bend
0.5 metre
1.0 metre
Vertical flue terminal and accessories
Part No.
Description
Min-Max length
0225725
0225770
0225765
0225755
0225740
0225745
0225750
0225730
0225735
0225760
Vertical flue terminal
Pitched roof flashing plate
Flat roof flashing plate
350-500 telescopic extension
500 mm extension
1000 mm extension
2000 mm extension
45° bend (pair)
90° bend
Wall bracket (4)
1000 mm
N/A
N/A
350 mm-500 mm
500 mm
1000 mm
2000 mm
N/A
N/A
N/A
Fig. 8
520 mm
300 mm minimum
170mm
Fig. 7B
“Y” = “X” + 45 mm
Boiler
Extension pipe
Boiler top adaptor
Push-fit connection
Plain end