Technical data
21
Linea
6.9 PRESSURE GAUGE fig. 23
Carry out component removal procedure as de-
scribed in 6.4.
Remove pressure gauge locking screw (1), lo-
cated on pump base, and withdraw the pressure
gauge pipe (2), locate the spring tabs on the pres-
sure gauge body, push and hold tabs in, to en-
able extraction of the gauge from its location.
Replace in the reverse order.
6.10 PRIMARY THERMISTOR fig. 24
Carry out component removal procedure as de-
scribed in 6.4.
Unclip and remove the air chamber cover, and
remove the right side air baffle.
Disconnect thermistor electrical plug. Using a
13mm spanner slacken and remove the thermis-
tor and sealing washer (1,2) from the main heat
exchanger. Replace in the reverse order.
Fig. 25
6.11 HIGH LIMIT THERMOSTAT fig. 25
Carry out component removal procedure as de-
scribed in 6.4.
Unclip and remove the air chamber cover.
Pull off electrical connections from the high limit
thermostat (2), slacken and remove retaining
screws (3). Replace in reverse order.
6.12 PRINTED CIRCUIT BOARD fig. 26
Carry out component removal procedure as de-
scribed in 6.4.
Locate and remove the screws (1) which secure
the PCB cover & terminal cover, then remove
cover, after carefully taking note of all wiring con-
nections, disconnect all wiring from the PCB,
locate and remove the PCB securing screws
(2,3,), remove the required PCB (4,5,6). Replace
in the reverse order.
Fig. 23
Fig. 24
Fig. 26