Technical data
Linea 24 & 28
45
DO NOT USE SMALLER TERMINAL
BLOCK MARKED 'POS' 'POS' '-''S' WHEN
CONNECTING INTERNAL OR EXTER-
NAL ELECTRICAL CONTROLS.
IMPORTANT
Fig. 5 Showing 230v input electrical con-
nection without room thermostat or internal
time clock
(Internal wiring loom for timeclock and link
between = & TA remains)
Fig. 6 Showing 230v input electrical
connection and room thermostat con-
nection (connected between TA & TA)
without internal time clock. (Remove
link between = & TA)
Note: Room thermostat contact rated at
230v. Should the room thermostat re-
quire a neutral or earth, connect neutral
to one of the terminals marked N, and
the earth to the earthing strip.
Fig. 7 Showing 230v input electrical con-
nection and internal timer without room
thermostat.
Note: DO NOT remove link between ter-
minals = & TA.
Fig. 8 Showing 230v input electrical con-
nection internal timer and room thermo-
stat.
Note:
i) Room thermostat contact rated at
230v. Should the room thermostat
require a neutral or earth, connect
neutral to one of the terminals marked
N, and the earth to the earthing strip.
ii) Terminal marked = is a spare terminal
used to connect controls. (Remove
link between = & TA )
Fig. 5
To internal timeclock
multiplug connector
(unused)
Fig. 6
Room thermostat
Fig. 7
Internal
time clock
Fig. 8
Room thermostat
Internal
time clock