Technical data
29
Code Reason
10 no flame detected
14 check the wiring harness
15 false flame
20 high limit thermostat/fume thermostat
21 check the wiring harness
22 check the wiring harness
24 high limit flow temperature probe
26 high limit return temperature probe
28 flow/return ΔT error
29 check the wiring harness
34 fan error (start-up)
37 fan error (high rpm)
40 low water pressure
42 pressure transducer fault
50-59 internal PCB failure
70 flow NTC error (2
nd
CH)
72 return NTC error (2
nd
CH)
79 flow/return ΔT error (2
nd
CH)
80-83 internal fault
91 condensing heat exchanger cleaning requirement
Code Reason
11 false flame
12 restart ignition
13 check the wiring harness
23 check the wiring harness
25 high limit flow temperature probe
27 high limit return temperature probe
41 low water pressure
60 DHW NTC error
71 flow NTC error (2
nd
CH)
77 over heat underfloor thermostat (2
nd
CH)
78 flow/return ΔT error (2
nd
CH)
Alarm 91 - Contact the Technical Assistance
The boiler has a self-diagnosis system which, on the basis of the
hours totalised in particular operating conditions, signals the need
for maintenance or cleaning of the primary exchanger (alarm code
91).