5.1 Electrical safety
To avoid electrical hazards please note the following:
Do not access the inside of any electrical equipment. Refer servicing to
Void-approved service agents.
5.2 Cable considerations for fixed installations
We recommend specifying installation-grade Low Smoke Zero Halogen (LSZH) cables for
permanent installations. The cables should use Oxygen Free Copper (OFC) of grade C11000
or above. Cables for permanent installations should be compliant with the following standards:
IEC 60332.1 Fire retardancy of a single cable
IEC 60332.3C Fire retardancy of bunched cables
IEC 60754.1 Amount of Halogen Gas Emissions
IEC 60754.2 Degree of acidity of released gases
IEC 61034.2 Measurement of smoke density.
We suggest using the following maximum copper cable lengths to keep level losses below 0.6 dB.
Metric mm
2
Imperial AWG 4 Ω load 2 Ω load
2.50 mm
2
13 AWG 18 m 9 m
4.00 mm
2
11 AWG 30 m 15 m
5.3 Impedance graph
5 Cabling and wiring
10 10020 50
200 500 1k 2k 5k 10k 20k
5
10
15
20
25
Frequency (Hz)
Impedance (Ω)
Figure 5.1: Impedance graph