User`s manual
QX Hawk Industrial Imager User’s Manual 7-23
Utilities
Default/Reset/Save
Understanding and controlling the imager’s active, saved, and default settings is critical to
its successful operation.
Resets
Resets (“A” commands) affect only the current settings (active memory) and are not saved
for power-on.
Saved for Power-on
Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded
into current parameters when power is cycled to the imager or the <Arp> command is
issued.
Defaults
Defaults are Microscan firmware settings or saved customer settings that can be recalled,
either by software or hardware reset.
Function
Serial
Cmd
ESP
a
a. When right-clicking in a tree control to select Default Current Menu Settings or Default All ESP
Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the
imager itself, follow up with a Save to Reader, Send and Save command.
EZ Button
Resets
(Not Saved
for Power-On)
Reset (Will not save for power-on) <A>
Save to Reader,
Send No Save
No
Reset and Recall Microscan Default
Parameters
<Ard> Send <Ard> from Terminal No
Reset and Recall Power-On Parameters
<Arp> Send <Arp> from Terminal No
Reset and Recall Customer Default
Parameters
<Arc> Send <Arc> from Terminal No
Saved for Power-On
Save Current Settings for Power-On <Z>
Save to Reader,
Send and Save
No
Save Current Settings as Customer
Default Parameters for Power-On
<Zc>
Save to Reader,
Send and Save Customer
Defaults for Power-On
b
b. Only available in ESP if enabled in
Preferences
(
General
tab), accessible from the Options dropdown menu.
No
Recall Microscan Default Settings
and Save for Power-On (Will not
default “sticky settings”)
<Zrd> Send <Zrd> from Terminal No
Recall Customer Default Settings
and Save for Power-On
<Zrc> Send <Zrc> from Terminal
Press and
hold while
powering