Table 2-8: Dialing Specifications
Item
Specification
DTMF Dialing
Frequency Deviation
Rise Time
Duration of DTMF Signal
Interdigit Time
Less than +/-1%
Maximum 3ms
Minimum 75ms
Minimum 75ms
Pulse Dialing
Pulse Dialing Rate
Pulse Break/Make Duration
10 or 20 pps
60/40% or 67/33%
CO Type Loop Start, 600 ohm, current sensing
Table 2-9: Trunk Ordering Info: Public Network/Private Lease Lines
System Port Identification, Facility Interface and Service Order Codes
Interface Card
Ringer Equivalent
Number (REN)
Facility Line
Interface
Jack Type
Ordering
Specification
CO Port (LCOBC) 0.8B 02LS2 RJ21X
Direct Inward Dial
(DIDB)
0.0B 02RV2-T RJ11
T-1 Port (T1IB) or
ISDN Port (PRIB)
6.0P 04DU9-B RJ45
T1 circuit used with
PRI networking
B8ZS, non-channelized, point-
to-point T1, 1.544 Mbps
Table 2-10: Dimension and Weight
Item
Height Width Depth Weight
in mm in mm in mm lbs kg
KSU 16.2 411 24.8 630 9.4 238 25.3 11.5
Digital Keyset 9.3 236 7.6 192 3.3 84 3.3 1.5
Digital DSS/BLF Console 9.3 236 4.9 125 2.4 62 2.0 0.9