Specifications

Monitor 4-7
Chapter 4 - Maintenance and Troubleshooting
Table 4-1: Command Event Trace Explanation
Raw event trace format:
789392 E>14 01 10, A0 02-8229
789392 : serial number
E> : event
14 : slot (gateway) number
01 : device type (eg, 01 = IPKTU, 40 = LGCM)
Device types:
01 = IP phone
03 = SLTM
40 = LGCM
42 = DIDM
61 = BRIM
70 = VOIP
D0 = VSF
E0 = MISC
10 : device sequence number (eg, 01 = STA100, 02 = STA101 ...)
Device sequence number types:
Station sequence numbers = 1-70 (same source and port # as in PGM 105)
CO Line sequence numbers = 1-42
A0 : event number
02- : length of the event
8229 : parameter(data) of the event
Analysis raw event trace format:
789392 STN:01 10 St:IDLE (00) Ev-I:CO KEY P1: A P2:0 EVT: 48
789392 : serial number
STN:01 10 : Station type 01 and number 10
st:IDLE : station state is IDLE
EVT-I:CO KEY : event type is internal event, event name is CO KEY event
P1: A P2:0 : Parameter 1 is A, parameter 2 is 0
EVT: 48 : The event call module number 48 in source
Raw command trace format:
789392 C>14 01 10, A0 05-0103600000
789392 : serial number
C> : Command
14 : Slot number
01 : device type (e.g., 01 = IPKTU, 40 = LGCM)
Device types:
01 = IP phone
03 = SLTM
40 = LGCM
42 = DIDM
61 = BRIM
70 = VOIP
D0 = VSF
E0 = MISC
10 : device sequence number (e.g., 10 = Station port number 10)
Device sequence number types:
Station sequence numbers = 1-70 (same source and port # as in PGM 105)
CO Line sequence numbers = 1-42
A0 : Command number
05- : length of the command
0103600000 : parameter(data) of the command