Specifications

4-4 Connection
Chapter 4 - Maintenance and Troubleshooting
Then load a communication software package (e.g., HyperTerminal) into the PC.
After opening HyperTerminal and the New Connection screen displays, complete the
following steps:
1. Type a connection name, select the appropriate icon, then click <OK>.
2. When the Phone Number screen displays, change the setting in the "Connect Using"
box to: COM1, and then click <OK>.
3. After the COM1 Properties screen displays, change the settings as shown in the
following bullets, and then click <OK>.
Bits per second = 38400
Data bits = 8
Parity = None
Stop bits = 1
Flow Control = None
4. Type the password (mainjob = the password), then press [Enter].
5. Type the desired password, then press [Enter] to access either the Monitoring or
Maintenance area.
Monitoring Password = jennie (lowercase letters)
Maintenance Password = brandy (lowercase letters)
Access Via IP Network
Load a communication software package (e.g., HyperTerminal) into any PC within the
Telenium
IP
Zone.
After opening HyperTerminal and the New Connection screen displays, complete the
following steps:
1. Type a connection name, select the appropriate icon, then click <OK>.
2. When the Phone Number screen displays, change the setting in the "Connect Using"
box to: TCP/IP (Winsock).
3. Enter the IP address of the MFIM in the box provided for "Host address", enter 5003
in the box provided for "Port number", then click <OK>.
4. Press [Enter] on the keyboard.
5. Type the password (mainjob = the password), then press [Enter].
6. Type the desired password, then press [Enter] to access either the Monitoring or
Maintenance area.
Monitoring Password = jennie (lowercase letters)
Maintenance Password = brandy (lowercase letters)