Specifications

3-14 Module Installation
Chapter 3 - Installation
Module
Module Module
Module Grounding
GroundingGrounding
Grounding
A "GND" screw is located on the rear panel of each Module. For proper operation and
code compliance, the grounding screw MUST be connected to a known earth ground
using a #18 AWG or larger UL-1015 type copper wire. Note that when using the Main
Cabinet, a separate ground connection to the individual Modules is not required.
Figure 3-10: Module Grounding
Telephony
Telephony Telephony
Telephony Connections
ConnectionsConnections
Connections
In general, PSTN and SLT (telephony) connections are available on the rear of each
Module. LAN, power, and RS-232 connections are on the front of each Module.
Telephony connections are via RJ-11 type jacks wired as in
Figure 3-11. These telephony
jacks are also employed for the miscellaneous functions of the MFIM Module. Details for
the terminations of the miscellaneous function jacks are given in
MFIM Installation on
page 3-20
.
All telephone wiring should use standard two twisted pair 24 AWG wiring.
Figure 3-11: Telephony (RJ-11) Connector Pin Assignment
Toothed lock
washer
Plan washer
rear panel
Wire position