Specifications
Main Cabinet Installation 3-5
Chapter 3 - Installation
Cabinet 19” Rack Installation
Cabinet 19” Rack InstallationCabinet 19” Rack Installation
Cabinet 19” Rack Installation
Rack mount brackets are provided as standard equipment with the Main Cabinet. These
brackets attach to the front sides of the Main Cabinet.
To rack mount the Main Cabinet:
1. Bolt the Rack mount brackets securely onto the sides of the Cabinet with the four
supplied M4 x 6 mm machine screws, nuts, and washers.
2. Connect the brackets securely to a standard 19” rack with four appropriate
machine screws, nuts, and lock-washers.
Figure 3-2: Rack 19" Installation
Cabinet Wall Mount Kit Installation
Cabinet Wall Mount Kit InstallationCabinet Wall Mount Kit Installation
Cabinet Wall Mount Kit Installation
If the Main Cabinet is to be wall mounted, a wooden backboard MUST be installed when
the location has masonry or plasterboard walls. This backboard is recommended for all
wall mount installations. A 1/2-inch plywood material is sufficient for most installations.
The backboard should be mounted at a convenient height, about one meter above the
floor, and be bolted to wall-studs in a number of places to distribute the weight of the
system.
Space should be available on the backboard for separate Telephone and LAN wiring main
distribution frames and for optional equipment such as music sources, etc.
The optional Cabinet Wall Mount kit mounts to the wall then the Main Cabinet is attached
to the Wall Mount kit. The Wall Mount kit permits the cabinet to swing on a Hinge for
access to the backplane telephony cabling. The Hinge may be placed on either side of the
Cabinet prior to installation. Select the Hinge side so as to obtain maximum clearance
and lighting.