Specifications
Issue 2 - May, 2004 Talkpath - Digital Voice Processing System Technical Manual
D-8 System Log and Error Messages
Error Messages
000 Sys: *System Var already defined*
Duplicate system variable names found while loading
HELLO.SDF. HELLO configuration
error (via MAINT).System Errors.
000 Sys: *Too Many System Vars (%d) for *
More system variables in
HELLO.SDF than HELLO can store. HELLO limit reached.
(maximum 50 system variables).
000 Sys: Critical Error Count = %d
Hourly log message indicating how many DOS critical errors trapped by optional error
handler. Not an error by itself, but does indicate some system errors.
000 Sys: New Years Day!
Log message indicating New Year rollover. Not an error.
001 Sys: (%s) * Invalid Port = %d *
Invalid comm port specified in RS232 operation. Module error.
001 Sys: (%s) * Port %d Already Locked by %d *
Comm port already locked by other line. Not an error, just competition for ports.
001 Sys: (%s) * Port %d NOT Locked (%d) *
Comm port not locked as expected. Module error.
001 Sys: (%s) * Port %d NOT Open *
Comm port not open as expected. Module error.
001 Sys: (Close) *Port %d LOCKED by line %d*
Comm port locked by other line during close. Not an error, just indicates multiple lines
accessing comm port.
001 Sys: (Open) *Port %d Already Opened by line %d*
Comm port already open during another open operation. Module error.
001 Sys: *Open error %d on port %d*
Error opening comm port for operations. Low level software (LCOM) or hardware error.