Specifications

Database Upload/Download Routine E-11
Customer Database Programming
STARPLUS STSe - Programming & Operations Manual August 2005
ECOM -- Downloading a Database File
After opening ECOM:
1. Press< Alt> + <P> to open COM Port Options.
2. Change COM port settings as follows, and click <OK>.
Baud Rate = 9600
Parity = None
Data Bits = 8
Stop Bits = 1
Flow Control = no boxes checked, Xon=17, Xoff=19
3. Press <Enter> and complete the following fields:
4. Press <PgDn> on keyboard or locate file and select Download.
5. Highlight XMODEM and click <OK>.
6. Type or select download filename and click <OK>. The Adm> prompt displays when the
file transfer is complete.
Screen Fields Action
ENTER PASSWORD: Type password: XXXXVODAVI
(XXXX = default password for online administration)
ADM>, Type program number.
ADM>86 Load database routine.
Type button number.
ADM>W Download database.
Press HOLD button.
ADM> Press <Enter> key twice.