Specifications
2-280 Station Attributes
Features and Operation
STARPLUS STSe - Programming & Operations Manual August 2005
Station Attributes
Initialize Station Attributes
Description
The Station Parameters may be initialized setting all data fields to their original, default
values. The following data fields are returned to their default value upon initializing the
Station Attributes.
Table 2-23: Station Attribute Defaults
Program
Code
Flexible
Button
Features
Default Value
(after initialization)
FLASH 50/51 1 Paging Access Enabled
PAGE A 2 Do Not Disturb Enabled
3 Conference Enable/Disable (Per Station) Enabled
4 Executive Override Disabled
5 Privacy (Per Station) Enabled
6 System Speed Dial Access Enabled
7 Line Queuing Enabled
8Preferred Line Answer Enabled
9 Off-Hook Voice Over (OHVO) Disabled
10 Call Forwarding Enabled
11 Forced Least Cost Routing Disabled
13 Executive Override Blocking Disabled
14 CO Line Ringing Options Muted Ring
15 Name/Number Display at Idle Name (Enabled)
17 CO, Loop, Pool Disabled
18 Admin Access Disabled
FLASH 50/51
PAGE B
1 Station Identification 0 (STSe 24-Btn Keyset)
6 (SLT w/o MW)
2 Station Day Class of Service (COS) COS 1
3 Station Night Class of Service (COS) COS 1
4 Speakerphone/Headset Programming 0=Full Speakerphone
5 Pick-Up Group(s) Programming Group 1
6 Paging Zone(s) Programming Zone 1
7 School Zone Disabled
8 Line Group Access - Station Group 1
9 LCR Class of Service (COS) 0 (Unrestricted Access)
10 Off-Hook Preference Programming 00=No specific button
preferred; Enabled
11 Flexible Button Programming (blank)
12 Keyset Mode Inactive Mode