Specifications
2-208 ISDN Programming - Page B
Features and Operation
STARPLUS STSe - Programming & Operations Manual August 2005
Link Disconnect
Description
Do not change the Link Disconnect Timer setting unless advised to do so by Technical
Support.
Programming Steps
1. Press the LINK DISCONNECT flexible button (FLASH 45, Page B, Button #14).
2. Enter a valid number (20-30 seconds) on the dial pad.
3. Press the HOLD button. A confirmation tone sounds and the display updates.
DEFAULT … Link Disconnect setting is 30 seconds.
Call Proceeding
Description
Do not change the Call Proceeding setting unless advised to do so by Technical Support.
Programming Steps
1. Press the CALL PROCEEDING flexible button (FLASH 45, Page B, Button #15).
2. Enter a valid number (00-99 seconds) on the dial pad.
3. Press the HOLD button. A confirmation tone sounds and the display updates.
DEFAULT … Call Proceeding setting is 60 seconds.
Connect Request
Description
Do not change the Connect Request Timer setting unless advised to do so by Technical
Support.
Programming Steps
1. Press the CONNECT REQUEST flexible button (FLASH 45, Page B, Button #16).
2. Enter a valid number (00-99 seconds) on the dial pad.
3. Press the HOLD button. A confirmation tone sounds and the display updates.
DEFAULT … Connect Request setting is 4 seconds.
LINK DISCONNECT 20-30
T309 30
CALL PROCEEDING 00-99
T310 60
CONNECT REQUEST 00-99
T313 04