Specifications

2-204 ISDN Programming - Page B
Features and Operation
STARPLUS STSe - Programming & Operations Manual August 2005
Maximum TEI Request
Description
This feature is reserved for future use.
Programming Steps
1. Press the MAX TEI RQST flexible button (FLASH 45, Page B, Button #3).
2. Enter a valid number (000-999) on the dial pad.
3. Press the HOLD button. A confirmation tone sounds and the display updates.
DEFAULT … Maximum TEI Request setting is 003.
Maximum XID Retransmission
Description
Do not change the Maximum number of XID Retransmissions setting unless advised to do so
by Technical Support.
Programming Steps
1. Press the MAX XID RETRANSMISSION flexible button (FLASH 45, Page B, Button #4).
2. Enter a valid number (0-9 seconds) on the dial pad.
3. Press the HOLD button. A confirmation tone sounds and the display updates.
DEFAULT … Maximum XID Retransmission setting is 3 seconds.
T-2 00
Description
The T-200 timer is used to set the time to wait for an I-Frame acknowledgement. Do not
change the T-200 timer setting unless advised to do so by Technical Support.
Programming Steps
1. Press the T-200 flexible button (FLASH 45, Page B, Button #5).
2. Enter a valid number (00-99 seconds) on the dial pad.
3. Press the HOLD button. A confirmation tone sounds and the display updates.
DEFAULT … T200 setting is 1 second.
MAX TEI RQST 000-999
N202 003
MAX XID RETRANSMSN 0-9
N204 3
T200 00-99
01