Specifications

Idle Speaker Mode 2-183
Features and Operation
STARPLUS STSe - Programming & Operations Manual August 2005
Print Hunt Group Parameters
Description
The Print Hunt Group command dumps the entire database as a permanent record which can
serve as a hardcopy of the database. The system baud rate must match that of the printer or
receiving device.
Programming Steps
1. Press the HUNT GROUPS flexible button (FLASH 85, Button #11). The following message
displays:
2. To print data for Hunt Group Parameters, press the HOLD button. The following message
displays:
When the system finishes sending the requested information to the printer, a
confirmation tone sounds.
Idle Speaker Mode
Description
The Idle Speaker Mode feature allows you to select whether the first digit dialed is audible
over the digital telephone speaker. This feature is allowed or denied on a system-wide basis
in programming.
HUNT GROUPS
-----------
HG 0..450 PILOT RING ONE
HG 1..451 PILOT RING ONE
HG 2..452 PILOT RING ONE
HG 3..453 PILOT RING ONE
HG 4..454 PILOT RING ONE
HG 5..455 PILOT RING ONE
HG 6..456 PILOT RING ONE
HG 7..457 PILOT RING ONE
RAN HUNT GROUPS
---------------
HG 8..458 PILOT RING ONE
HG 9..459 PILOT RING ONE
HG10..460 PILOT RING ONE
HG11..461 PILOT RING ONE
Figure 2-11: Hunt Group Parameters Printout
PRINT HUNT GROUP
PRESS HOLD
PRINTING HUNT GROUP
When this feature is enabled, there can be some idle speaker noise.