Specifications

2-178 Hold - System
Features and Operation
STARPLUS STSe - Programming & Operations Manual August 2005
Hold - System
When a line is placed on System Hold, any station in the system with an appearance of that
line can retrieve the call.
System Hold Flash Rate
Description
The System Hold flash rate is the rate at which a CO Line button or Loop button flashes when
a call is placed on System Hold. This flash rate can be programmed to 29 different options
identified in the flash rate table. This enables the programmer to customize the key system
configuration to desired flash rates.
Programming Steps
1. Press the SYSTEM HOLD flexible button (FLASH 07, Button #13). The following displays:
2. Enter a valid number (00-28) on the dial pad to correspond to one of the 29 available
options (refer to Table 2-16 on page 2-163).
3. Press HOLD to save the entry. A confirmation tone sounds and the display updates.
DEFAULT … System Hold flash rate is set for a Red 60 ipm Double Wink (04).
System Hold Recall Timer
Description
The System Hold Recall Timer determines the time before a call placed on System Hold recalls
the station placing the hold. If unanswered by that station, the call recalls the Attendant.
The System Hold Recall Timer setting is variable from 000-300 seconds. An entry of 000
disables the timer and there is no recall.
Programming Steps
1. Press the SYSTEM HOLD RECALL TIMER flexible button (FLASH 01, Button #1). The
following message displays:
2. Enter a valid number on the dial pad that corresponds to 000-300 seconds.
3. Press HOLD to save the entry. A confirmation tone sounds and the display updates.
DEFAULT … System Hold Recall Timer is set for 60 seconds.
SYSTEM HOLD 00-28
RED 60 IPM DBL WINK
SYSTEM HOLD RECALL 000-300
060