DID Collect Timer
Description
The DID Collect Timer is only used when the DID Incoming Signaling is set for dial pulse. This
is a time-out timer that looks at the incoming digits one digit at a time. If a second digit isn’t
detected within the 150 ms, the telephone system attempts to process that digit. If a second
digit is detected, the system waits 150 ms to see if a third digit is received. Otherwise, the
telephone system attempts to process the two digits already received. This process continues
until no additional digits are received and the time-out timer expires. The DID Collect Timer
setting is variable from 100ms to 2.0 seconds.
Programming Steps
1. Press FLASH and dial [40]. The following message displays:
2. Enter a valid number for the range of lines being programmed. If only one line is being
programmed, enter that number twice (001 001).
3. Press Button #21 to select Page C. The display updates. The following message displays to
indicate current programming of that line or group of lines:
XXX-XXX = CO Line Range
4. Press the DID COLLECT TIMER Button (Button #9) in the flexible button field. The
following message displays:
5. Enter a valid number on the dial pad that corresponds to 010–200 (100 ms to
2.0 seconds).
6. Press HOLD button to save entry. A confirmation tone sounds and the display updates.
DEFAULT … DID Collect Timer is set for 150 milliseconds.
CO LINE ATTRIBUTES
SELECT A CO LINE RANGE
If HOLD is pressed without entering a CO line range, all CO lines are selected.
XXX - XXX PAGE C
ENTER BUTTON NUMBER
DID COLLECT TIMER 010-200
015