Specifications
Database Administration 2-107
Features and Operation
STARPLUS STSe - Programming & Operations Manual August 2005
Programming Steps
1. Press FLASH and dial [50] or dial [51]. Flexible button #24 (New Range) is lit and one of
the following messages displays:
2. Enter the range of fixed station numbers (100-149) to be programmed. If only one station
is being programmed, enter that number twice, e.g., [100 100].
-or-
Enter a valid flexible number (100-8999) to be programmed.
3. Press HOLD to save the entry. A confirmation tone sounds and the display updates.
Flexible button #19 is lit. The display updates to reflect current programming for Page A:
4. Press the ADMIN ACCESS flexible button (Button #18). The following message displays:
5. Enter a 0 or 1 on the dial pad to enable/disable this feature.
[0] = Disable
[1] = Enable
6. Press HOLD to save the entry. A confirmation tone sounds.
DEFAULT … This feature is disabled.
Conditions
» Only one station at a time can be programmed when using a flexible station number.
» When in Flash 51 programming, if you press HOLD without specifying a flexible number
to be programmed, you will get the station that is in port/station 100.
Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers
STATION ATTRIBUTES
SELECT A STATION RANGE
ENTER STATION NUMBER
If HOLD is pressed without entering a station range, all stations are selected.
Flash 50 - Fixed Numbers Flash 51 - Flexible Numbers
XXX - XXX PAGE A
ENTER BUTTON NUMBER
SXXX PAGE A
ENTER BUTTON NUMBER
XXX-XXX = fixed station range XXX = 3- or 4-digit flexible number
ADMIN ACCESS 0-1
DISABLED