Programming instructions
Mailboxes
NAME
Each class of service should have a descriptive name assigned to it (e.g., secretary class, executive
class, etc.). This name is displayed each time you call up an individual class of service programming
screen. The name may be up to 34 characters length, and must be unique.
MAXIMUM NUMBER OF MESSAGES
This is the maximum number of messages a mailbox can accommodate. A class of service can be pro-
grammed for a maximum of 60 messages. This value can be used to limit the amount of disk space a
mailbox can take up.
MAXIMUM MESSAGE LENGTH
This value defines the maximum length of a single message for each class of service. A message must
be at least as long as the Minimum Length, and can be at most 9999 seconds long. This value is en-
tered in seconds. The following illustrates the effect of Maximum Message Length on a mailbox.
Example: Mailbox 3003 has a COS allowing a Maximum Message Length of 20 seconds.
0 Mailbox 3003 may record and send messages of up to 20 seconds in duration.
0 Mailbox 3003 may receive messages of longer than 20 seconds from mailbox holders having a
COS with a greater Maximum Message Length value.
0 Non-subscribers may leave messages of up to 20 seconds for mailbox 3003.
MAXIMUM SILENCE DURING RECORDING
While recording a message, the system listens for silence. If the system detects a silent period for the
amount of time programmed in this field, it presumes the message is ended. This field should be left
programmed to 4.
[CLASS OF SERVICE SCREEN]
CLASS OF SERVICE [-] NAME:
A) MAXIMUM NUMBER OF MESSAGES......................6 0
[
B) MAXIMUM MESSAGE LENGTH.........................12 0
[
-; SECONDS
C) MAXIMUM SILENCE DURING RECORDING .............. ...4 [ ] SECONDS
D) MINIMUM MESSAGE LENGTH .........................
..O [-]
SECONDS
E) GREETING MAXIMUM LENGTH.........................6 0 [- ] SECONDS
F) SPECIFIED DELIVERY TIME UP TO...................6 0 [--] DAYS IN ADVANC
C) MAXIMUM SPECIFIED DELIVERY TIME MESSAGES........2 0
[
-1
H) REVIEW METHOD FIFO/LIFO ........................
..l
lFIF0 PLIFO
I) GUESTS 1-B .................................... ...4
ki
J) KEEP NEW MESSAGES...............................3 0
i-1 DAYS
K) KEEP SAVED MESSAGES.............................1 0
L-1 DAYS
L) PERSONAL GROUPS.................................1 8 [
]
M) DESTINATION........................'.............2 5 [-]
N) OK TO SEND MESSAGE TO SYSTEM GROUP LIST
........ ..Y
[IF
0) NOTIFICATION OF AUTOMATIC MESSAGE ERASE ........ ..Y [-] Y/N
P) AUTOMATIC ALERT OF MESSAGE ERASE IN ADVANCE .... ..O [-] DAYS
Q) NOTIFICATION OF NON RECEIPT OF MESSAGE AFTER
... ..l [-] DAYS
R) END OF RECORDING ALERT IN ADVANCE...............1 0
SECONDS
S) TYPE OF OUT DIALING ............................ ..O
kT1
T) SEND MSG TAG (1:CONF 2:PRE 3:PROOF 4:SDT) IN..123 4 [
-1 OUT l-1
U) MWI RESET OPTION ............................... ..l
t-1
: [FZ]Clear [F5]Save [FB]D~~ [F7]Scroll [FB]Find [F@]Prev [FlO]Next [Esc]Quit :
Figure 3-2 Class Of Service Programming Screen
3.2
INFOSTARIVX2
System Administrator’s Manual
revised 7191