Programming instructions
Initial Setup
2.9 PBX PARAMETERS SCREEN
The PBX Parameter; screen is used to describe the telephone system to the VX2 system. There are
several screens are already defined for certain telephone systems. These systems are listed in
Section 2.3 Auto Integration. If you are connecting the VX2 system to a telephone system not listed,
the values for this screen must be determined from the telephone system vendor (or telephone system
documentation).
DIAL AREA
System Code
This is the 3-character code assigned to a particular telephone system.
This code corresponds to the to the entry in the Link To PBX field of
the Line Set-up screen. This tells the system which set of PBX param-
eters to use for a given telephone interface port.
Use
Tone or Pulse
This field is used to select the VX2 dial signaling (DTMF or rotary).
For most applications the VX2 is going to dial DTMF tones to the
telephone system. This field defaults to tone.
Transfer Sequence
Outbound Calls Prefix
This is the dial code sequence the telephone system uses to transfer a
call from the extensions that are connected to the VX2 system to oth-
er telephone system extensions. An “&” is used to insert a flash.
A “ ,” is used to insert a pause. This field defaults to flash and pause.
This is the dial code sequence the telephone system uses to place an
outside line call from the extensions that are connected to the VX2
system. This field defaults to flash and pause.
Internal Calls Prefix
This is the dial code sequence the telephone system uses to place an
internal call from the extensions that are connected to the VX2 sys-
tem. This field defaults to flash and pause
Reconnect
This is the dial code sequence the telephone system uses to reconnect
to a call placed on hold. This field defaults to flash.
[PBX PARAMETERS SCREEN]
SYSTEM CODE ) IDS
YIr.b
USE TONE OR PULSE..............T IT1 T-P
TRANSFER SEQUENCE..............&, [&:# PBX AREA CODE
OUTBOUND CALLS PREFIX..........&, [@, -
] [
-1
1
INTERNAL CALLS PREFIX..........&, [,
1
RECONNECT ................... ...& [&,*-I
BEFORE DIALING/RECEIVING
MINIMUM ON-HOOK DURATION (SEC).1 [03]
WAIT FOR DIAL TONE (SEC)......2 [02]
PAUSE....., [,-I
WINK @SEC) [ ]
HANG-UP-
SILENCE ON DURATION............0
SILENCE OFF DURATION...........0 ["o"o"o;
# OF REPETITION TO CHECK.......0
loo1
MAX NON SILENCE PERIOD (SEC)...0 [08] (RECORD)
MAX NON SILENCE PERIOD (SEC)...0 [lo] (PLAYBACK)
COYMUNICATION-
PORT NUMBER....1 [l]
BAUD RATE..00000 [00000]
STOP BIT.......1 [l]
PARITY.........0 [0]
DATA WORD......8 [8]
X-ON..........30 [30]
X-OFF.........70 [70]
BUFFER IN.. .1024 [1024] BUFFER OUT..1024 [1024]
= [FS]Clear [FS]Save [~8]~el [F'I]Scroll [FB]Find [FB]Prev [FlO]Next
[Esc]Quit
Figure 2-7 PBX Parameters Screen
INFOSTARIVX2
System Administrator’s Manual
revised 7191
2.9