Outdial
9.4.5 OUTDIAL PARAMETERS SCREEN
The Outdial Parameters screen is used to program the maximum number of retires and the time be-
tween retries for outdial calls which receive a busy signal or there is no answer. The Outdial Parame-
ters screen is programmed by Class of Service and not by mailbox number. To reach this screen from
the On Line Programming menu, press the
Fl
key.
The screen is divided into fields:
CLASS OF SERVICE
This is the class of service the screen is to be programmed for.
STATUS
This is the response the system gets when attempting to place an out-
dial call.
MAX RETRIES
This is the maximum number of times the system will attempt to call a
subscriber when the associated status is received.
DELAY BETWEEN TRIES
This is the how long in seconds the system waits before attempting
another outdial call to a subscriber when the associated status is re-
ceived.
[OUT DIAL PARAMETERS SCREEN]
CLASS OF SERVICE........[lOO]
[Status] [Max Retries] -
[Delay Between Tries]
BUSY...............
[0005]
NO ANSWER..........
OPERATOR INTERCEPT.
NO DIAL TONE.......
ANSWRING MACHINE...
1-l
q
[FB]Clear [FB]Save [FG]Del [FII]Scroll [FB]Find [FB]Prev [FlO]Next [Esc]Quit :
Figure 9-7 Out Dial Parameters Screen
ADDING OUTDIAL PARAMETERS TO A CLASS OF SERVICE
From the Main Menu press the
Fl
key, press 8, press 7, then press 4 (or press
Fl
from the On Line
Programming menu). The screen appears. See Figure 9-7. If there is an existing record, it is dis-
played. Press F3, and then Y to clear the screen. If there are no existing records, the screen is blank.
1. Enter the desired 3-digit class of service. The system should display the message, “Information not
found, press
RETURN
to continue.”
2.
Press the
RETURN
key. The cursor moves to Max Retries for Busy.
3. Enter the desired maximum number of retries for this class of service, then press the
RETURN
key.
The cursor moves to Delay Between Tries for Busy.
INFOSTARIVX2