User's Manual
Table Of Contents
- Contents
- About Honeywell Documentation
- Introduction
- Using the Talkman A500
- Charging an A500 or T5 Device
- Charging an A500 or T5 Battery in a Device
- Charging an A500 or T5-Series Battery
- Removing an A500, T2-Series or T5-Series Device From a Charger
- Inserting a Battery into a Talkman A500, T5-Series or T2-Series Device
- Removing a Battery from a Talkman A500, T5-Series or T2-Series Device
- Battery Warm-Up Time
- Easy Configuration
- Turning a Talkman Device On
- Turning a Talkman Device Off
- About LED Indicators
- Loading an Operator's Templates
- Adjusting the Voice
- Understanding Talkman Commands
- Options for Hearing Impaired Users
- Cleaning Procedures for Honeywell Equipment
- Charging an A500 or T5 Device
- Talkman A500 VMT
- Mounts for Talkman A500/T5 VMT
- Talkman A500/T5 VMT Accessories
- Positioning the Talkman A500/T5 VMT
- Installing the Mounting Brackets for a Talkman A500/T5 VMT
- Connecting Cables to the Power Supply and Attaching the Power Supply to a Vehicle
- Connecting the A500/T5 VMT Device to a Vehicle's Power Source
- Removal of an A500/T5 VMT Device from Vehicle
- VMT Installation Best Practices
- Chargers
- Troubleshooting Equipment Problems
- I Can't Hear Anything Through the Headset
- The Scanner will not Scan
- The Device Beeps Every Few Seconds
- The Device Will Not Load a Voice Application
- The Device Will Not Load an Operator Template
- The Device Does Not Respond to Button Presses
- The Device Will Not Turn On
- The Device Keeps Shutting Off
- Troubleshooting Guide for the Talkman A500/T5 Battery Charger
- Troubleshooting Problems Indicated by LED
- About Error Messages
- Contacting Technical Support
- About Sending Equipment Back for Repairs
- Troubleshooting VMT Configurations
- Specifications
- Accessories
- Part Numbers
- Template Training Options
- Compliance
- Index
SolutionError Message
"Initializing operator failed. Please reload
operator."
1.
Reload the operator.
2.
Turn the device off and then turn it back on again.
3.
Reboot the device.
4.
Reload VoiceClient.
"Internal error loading operator."
1.
Turn the device off and then turn it back on again.
2.
Reboot the device.
3.
Reload VoiceClient.
Select the operator again or load a different operator."Invalid operator file name."
"Invalid device Manager Host name or
address."
"Invalid device Manager Service name or
port."
"No task list file found. Task unchanged."
1.
Reload the task.
2.
Turn the device off and then turn it back on again.
3.
Reboot the device.
4.
Reload VoiceClient.
"Noise sampling procedure failed."
1.
Sample noise again.
2.
Go to a quieter location and perform another noise sample.
3.
Try using another headset and perform the noise sample.
Note: If this solves the problem, the first headset might be
damaged.
"Noise sampling procedure timed out."
1.
Sample noise again.
2.
Reboot the device.
"Operator load failed."
1.
Go to an area of known good coverage.
2.
Turn the device off and then turn it back on again.
3.
Reboot the device.
4.
Reload VoiceClient.
"Power-off error."
1.
Power on the device.
2.
Reboot the device.
Edit the task configuration file, taskname.vcf, and change the
line selftest=1 to selftest=0.
"Self test mode set, but no script file
found."
"Software error while changing task. Task
unchanged."
1.
Go to an area of known good coverage.
2.
Turn the device off and then turn it back on again.
3.
Reload the task.
4.
Reboot the device.
5.
Reload VoiceClient.
Confidential: For informational use by Honeywell resellers and customers only