6.7

Table Of Contents
5 Set the BIOS to search for SCSI devices.
a In the Host Adapter Settings page, select Host Adapter BIOS.
b Press Enter to toggle the value to Enabled.
c Press Esc to exit.
6 Enable the selectable boot.
a Select Selectable Boot Settings and press Enter.
b In the Selectable Boot Settings page, select Selectable Boot.
c Press Enter to toggle the value to Enabled.
7 Select the Boot Port Name entry in the list of storage processors (SPs) and press Enter.
The Select Fibre Channel Device page opens.
8 Select the specific SP and press Enter.
If you are using an active-passive storage array, the selected SP must be on the preferred (active)
path to the boot LUN. If you are not sure which SP is on the active path, use your storage array
management software to find out. The target IDs are created by the BIOS and might change with
each reboot.
9 Perform the appropriate action depending on the number of LUNs attached to the SP.
Option Description
One LUN The LUN is selected as the boot LUN. You do not need to enter the Select LUN
page.
Multiple LUNs The Select LUN page opens. Use the pointer to select the boot LUN, then press
Enter.
10 If any remaining storage processors show in the list, press C to clear the data.
11 Press Esc twice to exit and press Enter to save the setting.
vSphere Storage
VMware, Inc. 58