6.7

Table Of Contents
ESXi with NPIV supports the following items:
n
NPIV supports vMotion. When you use vMotion to migrate a virtual machine it retains the assigned
WWN.
If you migrate an NPIV-enabled virtual machine to a host that does not support NPIV, VMkernel
reverts to using a physical HBA to route the I/O.
n
If your FC SAN environment supports concurrent I/O on the disks from an active-active array, the
concurrent I/O to two different NPIV ports is also supported.
When you use ESXi with NPIV, the following limitations apply:
n
Because the NPIV technology is an extension to the FC protocol, it requires an FC switch and does
not work on the direct attached FC disks.
n
When you clone a virtual machine or template with a WWN assigned to it, the clones do not retain the
WWN.
n
NPIV does not support Storage vMotion.
n
Disabling and then re-enabling the NPIV capability on an FC switch while virtual machines are
running can cause an FC link to fail and I/O to stop.
Configure or Modify WWN Assignments
Assign WWN settings to virtual machine. You can later modify the WWN assignments.
You can create from 1 to 16 WWN pairs, which can be mapped to the first 1 to 16 physical FC HBAs on
the host.
Typically, you do not need to change existing WWN assignments on your virtual machine. In certain
circumstances, for example, when manually assigned WWNs are causing conflicts on the SAN, you might
need to change or remove WWNs.
Prerequisites
n
Before configuring WWN, ensure that the ESXi host can access the storage LUN access control list
(ACL) configured on the array side.
n
If you want to edit the existing WWNs, power off the virtual machine.
Procedure
1 Right-click the virtual machine in the inventory and select Edit Settings.
2 Click VM Options and expand Fibre Channel NPIV.
3 Create or edit the WWN assignments by selecting one of the following options:
Option Description
Temporarily disable NPIV for this
virtual machine
Disable but do not remove the existing WWN assignments for the virtual machine.
Leave unchanged Retain the existing WWN assignments. The read-only WWN assignments section
displays the node and port values of any existing WWN assignments.
vSphere Storage