6.7

Table Of Contents
Perform Adapter Rescan
When you make changes in your SAN configuration and these changes are isolated to storage accessed
through a specific adapter, perform rescan for only this adapter.
Procedure
1 Navigate to the host.
2 Click the Configure tab.
3 Under Storage, click Storage Adapters, and select the adapter to rescan from the list.
4 Click the Rescan Adapter icon.
Change the Number of Scanned Storage Devices
The range of scanned LUN IDs for an ESXi host can be from 0 to 16,383. ESXi ignores LUN IDs greater
than 16,383. The configurable Disk.MaxLUN parameter controls the range of scanned LUN ID range. The
parameter has a default value of 1024.
The Disk.MaxLUN parameter also determines how many LUNs the SCSI scan code attempts to discover
using individual INQUIRY commands if the SCSI target does not support direct discovery using
REPORT_LUNS.
You can modify the Disk.MaxLUN parameter depending on your needs. For example, if your environment
has a smaller number of storage devices with LUN IDs from 1 through 100, set the value to 101. As a
result, you can improve device discovery speed on targets that do not support REPORT_LUNS. Lowering
the value can shorten the rescan time and boot time. However, the time to rescan storage devices might
also depend on other factors, including the type of the storage system and the load on the storage
system.
In other cases, you might need to increase the value if your environment uses LUN IDs that are greater
than 1023.
Procedure
1 Navigate to the host.
2 Click the Configure tab.
3 Under System, click Advanced System Settings.
4 In the Advanced System Settings table, select Disk.MaxLUN and click the Edit icon.
5 Change the existing value to the value of your choice, and click OK.
The value you enter specifies the LUN ID that is after the last one you want to discover.
For example, to discover LUN IDs from 1 through 100, set Disk.MaxLUN to 101.
vSphere Storage
VMware, Inc. 133