6.7

Table Of Contents
Procedure
n
Create or edit alarms in the Monitor tab.
a Select an inventory object, click the Monitor tab, and click Issues.
b Click Alarm Definitions.
c Right-click the list of alarms, and select to add or edit an alarm.
You cannot edit vCenter Server predefined alarms.
n
Add an alarm to an object in the object navigator.
a Right-click an inventory object and select Alarms > New Alarm Definition.
Specify Alarm Name, Description, and Type
General settings of an alarm definition include alarm name, description, and type. You can also enable
and disable the alarm from the general settings page.
Prerequisites
n
Required Privilege: Alarms.Create alarm or Alarms.Modify alarm
n
In the alarm definition wizard, click the General page. See Create or Edit Alarms.
Procedure
1 Type a name and description.
2 Select the type of inventory object that this alarm monitors.
3 Select the type of activity that this alarm monitors.
Note Depending on the type of activity that you choose to monitor, the options on the Triggers page
that follow the General page in the alarm definitions wizard, change.
4 Click the Enable this alarm check-box if you want to enable the alarm immediately after creation.
5 Click Next.
What to do next
Set alarm triggers.
Specify How a Condition-Based or State-Based Alarm is Triggered
You can select and configure the events, states, or conditions that trigger the alarm from the Triggers
page of the alarm definition wizard.
The option that you choose on the General page of the alarm definition wizard determine the options
available on the Triggers page. An alarm definition must contain at least one trigger before you can save
it.
vSphere Monitoring and Performance
VMware, Inc. 133