7.1

Table Of Contents
Reconfigure External Workflow Timeouts
You must recongure the vRealize Automation external workow timeouts because the upgrade process
overwrites xmldb les.
Procedure
1 Open the external workow conguration (xmldb) les on your system from the following directory.
\VMware\vCAC\Server\ExternalWorkflows\xmldb\.
2 Recongure the external workow timeout seings.
3 Save your seings.
Verify That vRealize Orchestrator Service Is Available
After you upgrade to VMware vRealize ™ Automation 7.1, you must verify the connection between
vRealize Automation and VMware vRealize ™ Orchestrator ™. Sometimes after upgrade you must restore
the connection.
Prerequisites
Log in to the vRealize Orchestrator conguration interface.
Procedure
1 Click Validate .
2 If the Authentication section has a green check, go to step 4.
3 If the Authentication section does not have a green check, perform the following steps to restore the
connection to vRealize Orchestrator .
a Click Home.
b Click  Authentication Provider.
c In the Admin group text box, select Change, and choose a new Admin group that can be properly
resolved.
The vcoadmins group is available only at the default vsphere.local tenant. If you are using another
tenant for the vRealize Orchestrator, then you must select another group.
d Click Save Changes, and if prompted, restart the vRealize Orchestrator server.
e Click Home.
4 Repeat step 1 to conrm that the Authentication section still has a green check.
5 Click Home, and close the vRealize Orchestrator Control Center.
Restore Embedded vRealize Orchestrator Endpoint
If you add an embedded vRealize Orchestrator endpoint to a vRealize Automation 6.x deployment and
upgrade to vRealize Automation 7.1, you must make changes to the vRealize Orchestrator endpoint URL to
restore the connection.
In vRealize Automation 6.x, the URL for the embedded vRealize Orchestrator is hps://hostname:8281/vco. In
vRealize Automation 7.0, the URL for an embedded vRealize Orchestrator changes to hps://hostname/vco.
Because the 6.x URL does not change when you upgrade to 7.0, the system cannot nd
vRealize Orchestrator. Perform the following steps to x this problem.
Upgrading from vRealize Automation 6.2.x to 7.1
VMware, Inc. 41