7.3

Table Of Contents
3 Edit the Management Agent configuration file at C:\Program Files
(x86)\VMware\vCAC\Management Agent\VMware.IaaS.Management.Agent.exe.config to
replace the existing alternativeEndpointaddress value with the URL of the primary virtual appliance
endpoint.
The location of the installation folder might be different from the default location.
Example of alternativeEndpointaddress in VMware.IaaS.Management.Agent.exe.config.
<alternativeEndpoint address="https://FQDN:5480/" thumbprint="thumbprint
number" />
4 Restart the Management Agent Windows service and check the All.log file to verify that is working.
5 Run the upgrade procedure on the primary vRealize Automation appliance.
Empty Deployments Are Seen in vRealize Automation
After Upgrade
Post provisioning actions appear to complete successfully but no change actually takes place.
Problem
Upgrade process causes some virtual machines to become assigned to the wrong deployment. For
information, see Knowledge Base article 2151400.
After Rebooting the Virtual Appliance, Automatic IaaS
Upgrade Fails and Displays Pending Reboot Error
After you reboot the virtual appliance, the automatic IaaS upgrade command upgrade-server fails and a
Pending reboot error appears.
Problem
An anti-virus program running on the virtual appliance causes this problem. For information, see
Knowledge Base article 52211.
IaaS Repository Application Fails
The presence of Microsoft Monitoring Agent service can cause the IaaS repository application to fail.
Problem
IaaS repository fails and a "System.Web.Http.dll" version 4.0.0.0 error appears in the Repository.log. For
information, see Knowledge Base article 52444.
Upgrading from vRealize Automation 7.1, 7.2 to 7.3 or 7.1, 7.2, 7.3 to 7.3.1
VMware, Inc. 67