7.3

Table Of Contents
Cause
Many conditions can cause this problem. The error message identifies only the node ID of the affected
machine. More information is found in the All.log file for the Management Agent on the machine where
the command fails.
Perform these tasks on the affected nodes according to your situation:
Solution
n
If the Management Agent service is not running, start the service and restart upgrade on the virtual
appliance.
n
If the Management Agent service is running and the Management Agent is upgraded, restart upgrade
on the virtual appliance.
n
If the Management Agent service is running, but the Management Agent is not upgraded, perform a
manual upgrade.
a Open a browser and navigate to the vRealize Automation IaaS installation page on
thevRealize Automation appliance at https:// va-hostname.domain.name:5480/install.
b Download and run the Management Agent Installer.
c Reboot the Management Agent machine.
d Restart upgrade on the virtual appliance.
Management Agent Upgrade is Unsuccessful
The Management Agent upgrade is unsuccessful while upgrading from vRealize Automation to the latest
version.
Problem
If a failover incident has switched the primary and secondary Management Agent host, the upgrade is
unsuccessful because the automated upgrade process cannot find the expected host. Perform this
procedure on each IaaS node where the Management Agent is not upgraded.
Solution
1 Open the All.log in the Management Agent logs folder, which is located at C:\Program Files
(x86)\VMware\vCAC\Management Agent\Logs\.
The location of the installation folder might be different from the default location.
2 Search the log file for a message about an outdated or powered off virtual appliance.
For example, INNER EXCEPTION: System.Net.WebException: Unable to connect to the
remote server ---> System.Net.Sockets.SocketException: A connection attempt
failed because the connected party did not properly respond after a period of
time, or established connection failed because connected host has failed to
respond IP_Address:5480
Upgrading from vRealize Automation 7.1, 7.2 to 7.3 or 7.1, 7.2, 7.3 to 7.3.1
VMware, Inc. 66