7.3

Table Of Contents
e Change the ownership of the exported Orchestrator configuration file.
chown vco:vco orchestrator-config-export-orchestrator_appliance_ip-date_hour.zip
f Import the Orchestrator configuration file to the built-in vRealize Orchestrator server, by running
the vro-configure script with the import command.
./vro-configure.sh import --skipDatabaseSettings --skipLicense --skipSettings --
skipSslCertificate --notForceImportPlugins --notRemoveMissingPlugins --skipTrustStore --path
orchestrator-config-export-orchestrator_appliance_ip-date_hour.zip
3 If the external Orchestrator server from which you want to migrate uses the built-in PostgreSQL
database, edit its database configuration files.
a In the /var/vmware/vpostgres/current/pgdata/postgresql.conf file, uncomment the
listen_addresses line.
b Set the values of listen_addresses to a wildcard (*).
listen_addresses ='*'
c Append a line to the /var/vmware/vpostgres/current/pgdata/pg_hba.conf file.
host all all vra-va-ip-address/32 md5
Note The pg_hba.conf file requires using a CIDR prefix format instead on an IP address and a
subnet mask.
d Restart the PostgreSQL server service.
service vpostgres restart
Migrating vRealize Automation to 7.3 or 7.3.1