Cause
When you clone an IaaS node that has MS DTC installed, then both clones use the same unique
identifier for MS DTC. Communication between the nodes fails.
Solution
1 Open an Administrator command prompt.
2 Run the following command: msdtc -uninstall
3 Reboot the virtual machine.
4 Open a separate command prompt and run the following command:
msdtc -install <manager-service-host>.
Email Customization Behavior Has Changed
In vRealize Automation 6.0 or later, only notifications generated by the IaaS component can be
customized by using the email template functionality from earlier versions.
Solution
You can use the following XSLT templates:
n
ArchivePeriodExpired
n
EpiRegister
n
EpiUnregister
n
LeaseAboutToExpire
n
LeaseExpired
n
LeaseExpiredPowerOff
n
ManagerLeaseAboutToExpire
n
ManagerLeaseExpired
n
ManagerReclamationExpiredLeaseModified
n
ManagerReclamationForcedLeaseModified
n
ReclamationExpiredLeaseModified
n
ReclamationForcedLeaseModified
n
VdiRegister
n
VdiUnregister
Email templates are located in the \Templates directory under the server installation directory, typically
%SystemDrive%\Program Files x86\VMware\vCAC\Server. The \Templates directory also includes
XSLT templates that are no longer supported and cannot be modified.