Work Around Upgrade Problems
Automatic Manager Service Failover Does Not Activate
Suggestions for troubleshooting manager-service-automatic-failover command.
Solution
n
The manager-service-automatic-failover command fails or displays this message for more than two
minutes: Enabling Manager Service automatic failover mode on node:
IAAS_MANAGER_SERVICE_NODEID.
a Log in to vRealize Automation appliance management at https://va-hostname.domain.name:5480
with the user name host and the password you entered when you deployed the appliance.
b Select vRA Settings > Cluster.
c Verify that the Management Agent service is running on all Manager Service hosts.
d Verify that the last connected time for all IaaS Manager Service nodes is less than 30 seconds.
If you find any Management Agent connectivity issues, resolve them manually and retry the command
to enable the Manager Service automatic failover.
n
The manager-service-automatic-failover command fails to enable failover on a Manager Service
node. It is safe to rerun the command to fix this.
n
Some Manager Service hosts in the IaaS deployment have failover enabled while other hosts do not.
All Manager Service hosts in the IaaS deployment must have the feature enabled or it does not work.
To correct this issue, do one of the following:
n
Disable failover on all Manager Service nodes and use the manual failover approach instead.
Only run failover on one host at a time.
n
If multiple attempts fail to enable the feature on a Manager Service node, stop the Windows
VMware vCloud Automation Center Service on this node and set the node startup type to Manual
until you resolve the issue.
n
Use Python to validate that failover is enabled on each Manager Service node.
a Log in to the master vRealize Automation appliance node as root using SSH.
b Run python /usr/lib/vcac/tools/vami/commands/manager-service-automatic-
failover ENABLE.
c Verify that the system returns this message: Enabling Manager Service automatic
failover mode on node: IAAS_MANAGER_SERVICE_NODEID done.
n
Validate that failover is enabled on each Manager Service node by inspecting the Manager Service
configuration file.
a Open a command prompt on a Manager Service node.
b Navigate to the vRealize Automation installation folder and open the Manager Service
configuration file at VMware\vCAC\Server\ManagerService.exe.config.