7.2
Table Of Contents
- Upgrading from vRealize Automation 7.1 to 7.2
- Contents
- Updated Information
- vRealize Automation 7.1 Upgrade Prerequisites and Process
- Preparing to Upgrade vRealize Automation 7.1
- Updating the vRealize Automation 7.1 Appliance
- Upgrading the IaaS Server Components After Upgrading vRealize Automation 7.1 to 7.2
- Updating vRealize Orchestrator After Upgrading from vRealize Automation 7.1 to 7.2
- Add Users or Groups to an Active Directory Connection
- Enable Your Load Balancers
- Post-Upgrade Tasks for Upgrading vRealize Automation 7.1
- Troubleshooting the vRealize Automation 7.1 Upgrade
- Installation or Upgrade Fails with a Load Balancer Timeout Error
- Upgrade Fails for IaaS Website Component
- Manager Service Fails to Run Due to SSL Validation Errors During Runtime
- Log In Fails After Upgrade
- Unable to Upgrade Management Agent
- Delete Orphaned Nodes on vRealize Automation
- Join Cluster Command Appears to Fail After Upgrading a High-Availability Environment
- PostgreSQL Database Upgrade Merge Does Not Succeed
- Management Agent Upgrade is Unsuccessful
- Upgrade Fails to Upgrade the Management Agent or Certificate Not Installed on a IaaS Node
- Replica vRealize Automation Appliance Fails to Update
- Backup Copies of .xml Files Cause the System to Time Out
- Exclude Management Agents from Upgrade
- Unable to Create New Directory in vRealize Automation
- Index
System.Data.Common.Internal.Materialization.Shaper.RaiseMaterializedEvents()
at
System.Data.Common.Internal.Materialization.Shaper`1.SimpleEnumerator.MoveNext()
at System.Linq.Enumerable.FirstOrDefault[TSource](IEnumerable`1 source)
at System.Linq.Queryable.FirstOrDefault[TSource](IQueryable`1 source)
at
DynamicOps.Repository.Runtime.Common.GlobalPropertyHelper.GetGlobalPropertyItemValue(Core
ModelEntities
coreModelContext, String propertyName, Boolean throwIfPropertyNotFound)
at
DynamicOps.Repository.Runtime.CafeClientAbstractFactory.LoadSolutionUserCerticate()
at
DynamicOps.Repository.Runtime.CafeClientAbstractFactory.InitializeFromDb(String
coreModelConnectionString)
at DynamicOps.Repository.Runtime.Common.RepositoryRuntime.Initialize().
Cause
Iaas upgrade fails when the creation date for the web.config le is the same as or later than the modied
date.
Solution
1 Log in to the IaaS website component server as administrator.
2 Change directories to the vRealize Automation installation folder ...\VMware\vCAC\ .
3 Start your preferred text editor with the Run as Administrator option.
4 Locate and select the web.config le and save the le to change its le modication date.
5 Examine the web.config le properties to conrm that the le modication date is later than the
creation date.
6 Upgrade IaaS.
Manager Service Fails to Run Due to SSL Validation Errors During
Runtime
The manager service fails to run due to SSL validation errors.
Problem
The manager service fails with the following error message in the log:
[Info]: Thread-Id="6" - context="" token="" Failed to connect to the core database, will retry in
00:00:05, error details: A connection was successfully established with the server, but then an
error occurred during the login process. (provider: SSL Provider, error: 0 - The certificate
chain was issued by an authority that is not trusted.)
Cause
During runtime, the manager service fails to run due to SSL validation errors.
Chapter 9 Troubleshooting the vRealize Automation 7.1 Upgrade
VMware, Inc. 41