5.0

Table Of Contents
Procedure
1 In View Administrator, click View Configuration > Servers.
2 In the View Connection Servers panel, select the View Connection Server instance.
3 Click Disable.
You can enable the instance again by clicking Enable.
Edit the External URLs
You can use View Administrator to edit external URLs for View Connection Server instances and security
servers.
By default, a View Connection Server or security server host can be contacted only by tunnel clients that reside
within the same network. Tunnel clients that run outside of your network must use a client-resolvable URL to
connect to a View Connection Server or security server host.
When users connect to View desktops with the PCoIP display protocol, View Client can make a further
connection to the PCoIP Secure Gateway on the View Connection Server or security server host. To use the
PCoIP Secure Gateway, a client system must have access to an IP address that allows the client to reach the
View Connection Server or security server host. You specify this IP address in the PCoIP external URL.
Both the secure tunnel external URL and PCoIP external URL must be the addresses that client systems use to
reach this host. For example, if you configure a View Connection Server host, do not specify the secure tunnel
external URL for this host and the PCoIP external URL for a paired security server.
NOTE You cannot edit the external URLs for a security server that has not been upgraded to View Connection
Server 4.5 or later.
Procedure
1 In View Administrator, click View Configuration > Servers.
Option Action
View Connection Server instance
Select the View Connection Server instance in the View Connection Servers
panel and click Edit.
Security server
Select the security server in the Security Servers panel and click Edit.
2 Type the secure tunnel external URL in the External URL text box.
The URL must contain the protocol, client-resolvable host name or IP address, and port number.
For example: https://view.example.com:443
3 Type the PCoIP Secure Gateway external URL in the PCoIP External URL text box.
Specify the PCoIP external URL as an IP address with the port number 4172. Do not include a protocol
name.
For example: 100.200.300.400:4172
The URL must contain the IP address and port number that a client system can use to reach this security
server or View Connection Server instance. You can type into the text box only if a PCoIP Secure Gateway
is installed on the security server or View Connection Server instance.
4 Click OK to save your changes.
The external URLs are updated immediately. You do not need to restart the View Connection Server service
or the security server service for the changes to take effect.
VMware View Administration
22 VMware, Inc.