5.1

Table Of Contents
2 Run the /opt/vmware/vcloud-director/deploymentPackageCreator/createSysprepPackage.sh
SysprepBinariesDirectory command.
For example, /opt/vmware/vcloud-
director/deploymentPackageCreator/createSysprepPackage.sh /root/MySysprepFiles.
3 Use the service vmware-vcd restart command to restart the cloud cell.
4 If you have multiple cloud cells, copy the package and properties file to all cloud cells.
scp /opt/vmware/vcloud-director/guestcustomization/vcloud_sysprep.properties
/opt/vmware/vcloud-director/guestcustomization/windows_deployment_package_sysprep.cab
root@
next_cell_IP
:/opt/vmware/vcloud-director/guestcustomization
5 Restart each cloud cell to which you copy the files.
Replace a Microsoft Sysprep Deployment Package
If you already created a Microsoft Sysprep deployment package and you need to generate a new one, you must
replace the existing Sysprep package on each cloud cell in your installation.
Prerequisites
Access to the Sysprep binary files for Windows 2000, Windows 2003 (32- and 64-bit), and Windows XP (32-
and 64-bit).
Procedure
1 Use the service vmware-vcd stop command to stop the first cloud cell.
2 Copy the new Sysprep binary files for each operating system to a convenient location on a vCloud Director
server host.
Each operating system requires its own folder.
NOTE Folder names are case-sensitive.
Guest OS Copy Destination
Windows 2000 SysprepBinariesDirectory /win2000
Windows 2003 (32-bit) SysprepBinariesDirectory /win2k3
Windows 2003 (64-bit) SysprepBinariesDirectory /win2k3_64
Windows XP (32-bit) SysprepBinariesDirectory /winxp
Windows XP (64-bit) SysprepBinariesDirectory /winxp_64
SysprepBinariesDirectory represents a location you choose to which to copy the binaries.
3 Run the /opt/vmware/vcloud-director/deploymentPackageCreator/createSysprepPackage.sh
SysprepBinariesDirectory command.
For example, /opt/vmware/vcloud-
director/deploymentPackageCreator/createSysprepPackage.sh /root/MySysprepFiles.
4 Use the service vmware-vcd restart command to restart the cloud cell.
5 If you have multiple cloud cells, stop each cell and copy the package and properties file to each cell.
scp /opt/vmware/vcloud-director/guestcustomization/vcloud_sysprep.properties
/opt/vmware/vcloud-director/guestcustomization/windows_deployment_package_sysprep.cab
root@
next_cell_IP
:/opt/vmware/cloud-director/guestcustomization
6 Restart each cloud cell to which you copy the files.
Chapter 1 Getting Started with vCloud Director
VMware, Inc. 15