6.1

Table Of Contents
Table 133. Recovery Events (Continued)
Event Name Event Type Event Description Category
Recovery Plan
[data.Plan] failed
registering virtual
machine [data.Vm].
RecoveryVmRegisterFa
iled
Signaled in the case of SPPGs after a recovered
VM has failed registration with the recovery site
VC. If the plan is run against the local VC, then
[data.local] will be true.
Info
Recovery plan
hostnamehas been
created.
PlanCreated
Signaled when a new plan is created. It is sent to
each vCenter Server instance where the plan is
hosted.
Info
Recovery plan has
been destroyed.
PlanDestroy
Signaled when a plan has been deleted from the
site. Note that on the site where the plan has
been requested to be deleted there can be a
significant delay, while it waits for the plan to
be deleted at the other site. It will be sent to each
vCenter Server instance where the plan is
hosted.
Info
Recovery plan was
changed.
PlanEdit
Signaled when an existing plan is edited. Info
Recovery plan has
begun a test.
PlanExecTestBegin
Signaled on the recovery site when a recovery
test is initiated.
Info
Recovery plan has
completed a test.
PlanExecTestEnd
Signaled on the recovery site when a recovery
test has completed.
Info
Recovery plan has
begun a test cleanup.
PlanExecCleanupBegin
Signaled on the recovery site when a test
cleanup is initiated.
Info
Recovery plan has
completed a test
cleanup.
PlanExecCleanupEnd
Signaled on the recovery site when a test
cleanup has completed.
Info
Recovery plan has
begun a recovery.
PlanExecBegin
Signaled on the recovery site when a recovery is
initiated.
Info
Recovery plan has
completed a recovery.
PlanExecEnd
Signaled on the recovery site when a recovery
has completed.
Info
Recovery plan has
begun a reprotect
operation.
PlanExecReprotectBeg
in
Signaled on the recovery site when a reprotect is
initiated.
Info
Recovery plan has
completed a reprotect
operation.
PlanExecReprotectEnd
Signaled on the recovery site when a reprotect
has completed.
Info
Recovery plan is
displaying a prompt
and is waiting for user
input.
PlanPromptDisplay
Signaled on the recovery site when a prompt
step is encountered. The key is a unique
identifier for the prompt.
Info
Recovery plan has
received an answer to
its prompt.
PlanPromptResponse
Signaled on the recovery site when a prompt
step is closed.
Info
Recovery plan has
started to run a
command on the
Site Recovery
Manager Server
machine.
PlanServerCommandBeg
in
Signaled on the recovery site when
Site Recovery Manager has started to run a
callout command on the
Site Recovery Manager Server machine.
Info
Site Recovery Manager Administration