6.1

Table Of Contents
Option Action
Allow Site Recovery Manager to
automatically create tag categories
and the Replicated tag that Storage
DRS compatibility requires. The
default value is true.
Select the storage.enableSdrsStandardTagCategoryCreation check box.
Allow Site Recovery Manager to
automatically create and attach tags
to replicated or protected
datastores for Storage DRS
compatibility. The default value is
true.
Select the storage.enableSdrsTagging check box. If you clear the check
box, Site Recovery Manager deletes all the tags and tag categories and
breaks compatibility with Storage DRS.
Allow Site Recovery Manager to
repair missing or incorrect tags on
replicated or protected datastores
for Storage DRS compatibility. The
default value is true.
Select the storage.enableSdrsTaggingRepair check box.
Change the maximum number of
concurrent SRA operations. The
default value is 5.
Enter a new value in the storage.maxConcurrentCommandCnt text box.
Change the minimum amount of
time in seconds between datastore
group computations. The default
value is 0.
Enter a new value in the storage.minDsGroupComputationInterval text
box.
Change the interval between status
updates for ongoing data
synchronization operations. The
default value is 30 seconds.
Enter a new value in the storage.querySyncStatusPollingInterval text box.
Change the interval between
Storage DRS tagging related
operations. The default value is 50
seconds.
Enter a new value in the storage.sdrsTaggingPollInterval text box.
Change the interval between
storage array discovery checks.
The default value is 86400 seconds
(24 hours).
Enter a new value in the storage.storagePingInterval text box.
Change the maximum amount of
time permitted for data
synchronization operations to
complete. The default value is
86400 seconds (24 hours).
Enter a new value in the storage.syncTimeout text box.
5 Click OK to save your changes.
Change ABR Storage Policy Setting
You can modify the ABR Storage Policy setting to specify the interval (in seconds) to perform auto-
discovery of datastores that match a virtual machine storage policy.
Procedure
1 In the vSphere Web Client, click Site Recovery > Sites, and select a site.
2 On the Manage tab, click Advanced Settings.
3 Select ABR Storage Policy and click Edit.
4 Change the value for storagePolicyAbrReplication.policyDatastorePollInterval as needed. The default
value is 20 seconds.
5 Click OK to save your changes.
Chapter 12 Advanced Site Recovery Manager Configuration
VMware, Inc. 143