6.1

Table Of Contents
4 Click Edit to change the settings.
Option Action
Skip the check for non-protected
replica virtual machines while
deactivating the protection site
during Planned Migration. The
default value is false.
Select the checkbox to enable the value
replication.disablePiggybackVmsCheckDuringDeactivate.
Change the timeout in seconds to
wait when creating a placeholder
virtual machine. The default value is
300 seconds.
Enter a new value in the replication.placeholderVmCreationTimeout text
box.
Change the timeout in seconds to
wait for consistency group
information to be replicated to the
remote site before starting an
online sync on that site. The default
is 900 seconds.
Enter a new value in the replication.protectionInfoSyncTimeout textbox.
5 Click OK to save your changes.
Change SSO Setting
You can modify the Single Sign On setting for Site Recovery Manager to renew SSO tokens.
Procedure
1 In the vSphere Web Client, click Site Recovery > Sites, and select a site.
2 On the Manage tab, click Advanced Settings.
3 Click SSO.
4 Click Edit to change the sso.sts.tokenLifetime setting to specify the number of seconds to use SSO
tokens before they are renewed.
The default value is 28800 seconds (8 hours).
5 Click OK to save your changes.
Change Storage Settings
You can adjust the storage settings to modify how Site Recovery Manager and vCenter Server communicate
with the storage replication adapter (SRA).
Procedure
1 In the vSphere Web Client, click Site Recovery > Sites, and select a site.
2 On the Manage tab, click Advanced Settings.
3 Click Storage.
4 Click Edit to modify the storage settings.
Option Action
Change timeout in seconds for
executing an SRA command. The
default value is 300 seconds.
Enter a new value in the storage.commandTimeout text box.
Change timeout in seconds
between datastore monitoring
related operations. The default
value is 30 seconds.
Enter a new value in the storage.datastoreMonitoringPollingInterval text
box.
Site Recovery Manager Administration