Installation guide

Classification Event Category Event ID Message Description
[PET]
0x80020100
Voltage: Lower
Non-critical - going
high
Recovered from the lower
warning limit of the voltage.
[PET]
0x80020104
Voltage: Lower
Non-recoverable -
going high
Recovered from the lower
non-recoverable limit of the
voltage.
[PET]
0x00020107
Voltage: Upper
Non-critical - going
high
Exceeded the upper warning
limit of the voltage.
[PET]
0x80020107
Voltage: Upper
Non-critical - going
low
Recovered from the upper
warning limit of the voltage.
[PET]
0x8002010B
Voltage: Upper
Non-recoverable -
going low
Recovered from the upper
non-recoverable limit of the
voltage.
[PET]
0x00020301
Voltage: Monitoring
event occurred
An event of the voltage
occurred.
[PET]
0x80020301
Voltage: Monitoring
event cleared
Recovered from an event of
the voltage.
[PET]
0x00020501
Voltage: Limit
Exceeded
The voltage exceeded the limit.
[PET]
0x80020501
Voltage: Limit Not
Exceeded
The voltage did not exceed the
limit.
[PET]
0x00020601
Voltage: Performance
Lags
Detected the voltage warning.
[PET]
0x80020601
Voltage: Performance
Met
Recovered from the voltage
warning.
[PET]
0x80020700
Voltage: Transition to
Abnormal
The voltage became abnormal.
[PET]
0x00020701
Voltage: Transition to
Non-Critical
The voltage became the
warning level.
[PET]
0x00020702
Voltage: Transition to
Critical
The voltage became the critical
level.
Current Others [PET]
0x00030301
Current: Monitoring
event occurred
An event of voltage / electric
currents occurred.
[PET]
0x80030301
Current: Monitoring
event cleared
Recovered from an event of
voltage / electric currents.
[PET]
0x00030501
Current: Limit
Exceeded
Voltage / electric currents
exceeded the limit.
[PET]
0x80030501
Current: Limit Not
Exceeded
Voltage / electric currents did
not exceed the limit.
FAN Prediction:fan/co
oling device
failure
[PET]
0x00040102
Fan(Speed): Lower
Critical - going low
The number of revolution of
FAN fell below the lower critical
limit.
[PET]
0x00040104
Fan(Speed): Lower
Non-recoverable -
going low
The number of revolution of
FAN fell below the lower
non-recoverable limit.
[PET]
0x00040109
Fan(Speed): Upper
Critical - going high
The number of revolution of
FAN exceeded the upper
critical limit.