Installation guide
Appendix A Network Ports and Protocols
Note:
▪ To detect OOB Management events, see Section 3.10, "Preparing for the Use of
Out-of-Band (OOB) Management" in SigmaSystemCenter Configuration Guide and
perform the procedures from Subsection 3.10.1, "Configuring IP Address of BMC" to
Subsection 3.10.3, "Configuring Alert Destination of PET and Alert Level." However,
OOB Management events cannot be detected from a managed machine where NEC
ESMPRO Agent is working.
▪ If you are using ESX (Linux), disable the shutdown function of a machine to be
monitored during an error occurrence, referring to Subsection 3.2.2, "Other Setting" in
NEC ESMPRO Agent (for Linux) User's Guide to use events of SystemMonitorEvent.
▪ If you are using Hyper-V (Windows), disable the shutdown function of a machine to
be monitored during the error occurrence by performing the following procedure:
1. From Control Panel, double-click NEC ESMPRO Agent. Click the General tab and
Report Setting on the NEC ESMPRO Agent Properties dialog box to activate the
Alert Manager.
2. Select Base Setting, located on the setting menu on the Alert Manager.
3. Click the Function valid/invalid status on the setting of the time until shutdown,
located on the Other tab to change from green to red.