Technical data
Solution Technology Overview
VMware Horizon View 5.3 and VMware vSphere for up to 2,000 Virtual
Desktops Enabled by Brocade Network Fabrics, EMC VNX, and EMC Next-
Generation Backup
41
Figure 7. Example of Highly-Available Brocade network design – for FC
block storage network
Brocade 6510 Fibre Channel switches supports provide high availabity for
the VSPEX SAN infrastructure. Active – active links for all traffic from the
virtualized to compute servers to the EMC VNX storage arrays. The
Brocade
®
6510 Switch meets the demands of hyper-scale, private cloud
storage VSPEX storage traffic environments with market-leading Gen 5
Fibre Channel technology and capability that supports the VSPEX
virtualized architecture.
The failure of a link in a route causes the network to reroute any traffic that
was using that particular link—as long as an alternate path is available.
Brocade Fabric Shortest Path First (FSPF) is a highly efficient routing
algorithm that reroutes around failed links in less than a second.
ISL Trunking improves on this concept by helping to prevent the loss of the
route. A link failure merely reduces the available bandwidth of the logical
ISL trunk. In other words, a failure does not completely “break the pipe,”
but simply makes the pipe thinner. As a result, data traffic is much less likely
to be affected by link failures, and the bandwidth automatically increases
when the link is repaired.