Technical data
VSPEX Configuration Guidelines
VMware Horizon View 5.3 and VMware vSphere for up to 2,000 Virtual
Desktops Enabled by Brocade Network Fabrics, EMC VNX, and EMC Next-
Generation Backup
164
To enable jumbo frames on the VNX:
1. Navigate to Unisphere >Settings > Network > Settings for File.
2. Select the appropriate network interface under the Interfaces tab.
3. Select Properties.
4. Set the MTU size to 9,000.
5. Click OK to apply the changes.
Jumbo frames might also need to be enabled on each network switch.
Consult your switch configuration guide for instructions.
Connect the data stores configured in Prepare and configure the storage
to the appropriate vSphere servers. These include the datastores
configured for:
Virtual desktop storage
Infrastructure virtual machine storage (if required)
SQL Server storage (if required)
vSphere Storage Guide provides instructions on how to connect the
VMware datastores to the vSphere host. Refer to the list of documents in
Appendix C of this document for more information.
The vSphere EMC PowerPath VE (FC variant) and NFS VAAI (NFS variant)
plug-ins must be installed after VMware Virtual Center has been deployed
as described in
Connect
VMware
datastores