Technical data
VSPEX Configuration Guidelines
VMware Horizon View 5.3 and VMware vSphere for up to 2,000 Virtual
Desktops Enabled by Brocade Network Fabrics, EMC VNX, and EMC Next-
Generation Backup
143
SW6510:admin> ipaddrset
Ethernet IP Address [10.77.77.77]:10.18.226.172
Ethernet Subnetmask [255.255.255.0]:255.255.255.0
Gateway IP Address [0.0.0.0]:10.18.226.1
DHCP [Off]: off
If you are going to use an IPv6 address, enter the network information in
semicolon-separated notation as a standalone command.
SW6510:admin> ipaddrset -ipv6 --add 1080::8:800:200C:417A/64
IP address is being changed...
Configure Domain ID and Fabric Parameters
RCD-FC-6510:FID128:admin> switchdisable
BRCD-FC-6510:FID128:admin> configure
Configure...
Fabric parameters (yes, y, no, n): [no] y
Domain: (1..239) [1] 10
WWN Based persistent PID (yes, y, no, n): [no]
Allow XISL Use (yes, y, no, n): [no]
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
WAN_TOV: (0..30000) [0]
MAX_HOPS: (7..19) [7]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
Per-frame Route Priority: (0..1) [0]
Long Distance Fabric: (0..1) [0]
BB credit: (1..27) [16]
Disable FID Check (yes, y, no, n): [no]
Insistent Domain ID Mode (yes, y, no, n): [no] yes
Disable Default PortName (yes, y, no, n): [no]
Edge Hold Time(0 = Low(80ms),1 = Medium(220ms),2 =
High(500ms): [220ms]): (0..2) [1]
Virtual Channel parameters (yes, y, no, n): [no]
F-Port login parameters (yes, y, no, n): [no]
Zoning Operation parameters (yes, y, no, n): [no]
RSCN Transmission Mode (yes, y, no, n): [no]
Arbitrated Loop parameters (yes, y, no, n): [no]
System services (yes, y, no, n): [no]
Portlog events enable (yes, y, no, n): [no]
ssl attributes (yes, y, no, n): [no]
rpcd attributes (yes, y, no, n): [no]
webtools attributes (yes, y, no, n): [no]
Note: The domain ID will be changed. The port level zoning may be
affected.
Note: The Domain ID will be changed.