Technical data
VSPEX Configuration Guidelines
VMware Horizon View 5.3 and VMware vSphere for up to 2,000 Virtual
Desktops Enabled by Brocade Network Fabrics, EMC VNX, and EMC Next-
Generation Backup
127
BRCD6740-21# show fabric isl
Rbridge-id: 21 #ISLs: 2
Src Src Nbr Nbr Nbr-WWN BW Trunk Nbr-Name
Index Interface Index Interface
------------------------------------------------------------------
0 Fo 21/0/49 0 Fo 22/0/49 10:00:00:27:F8:BB:7E:85 40G Yes
"BRCD6740-22"
2 Fo 21/0/51 2 Fo 22/0/51 10:00:00:27:F8:BB:7E:85 40G Yes
"BRCD6740-22"
BRCD6740-21# show fabric trunk
Rbridge-id: 21
Trunk Src Source Nbr Nbr
Group Index Interface Index Interface Nbr-WWN
------------------------------------------------------------------
1 0 Fo 21/0/49 0 Fo 22/0/49 10:00:00:27:F8:BB:7E:85
2 2 Fo 21/0/51 2 Fo 22/0/51 10:00:00:27:F8:BB:7E:85
Figure 39. VDX 6740 vLAG for ESXi hosts
Create a port-channel
When creating a port channel interface on both Brocade VDX 6740
switches- RB21 and RB22 note that the port channel number should be the
same on both the VDXs, as shown below. Also note that because this
solution utilizes vCenter integration, the “switchport” command will not be
used and the port will not be configure as a trunk port. This is handled by
the vCenter integration.
Step 5: Create
vLAG for ESXi
Hosts