Technical data
VSPEX Configuration Guidelines
VMware Horizon View 5.3 and VMware vSphere for up to 2,000 Virtual
Desktops Enabled by Brocade Network Fabrics, EMC VNX, and EMC Next-
Generation Backup
126
Shown below are the port groups for the VDX 6740 and 6740T platforms.
1
Trunk Group 1 - 1/10 GbE SFP ports 1-16
4
Trunk group 4 - 1/10 GbE SFP ports 41-48
2
Trunk Group 2 - 1/10 GbE SFP ports 17-32
5
Trunk Group 3A - 40 GbE QSFP ports 49-50
3
Trunk Group 3 - 1/10 GbE SFP ports 33-40
6
Trunk Group 4A - 40 GbE QSFP ports 51-52
Figure 37. Port Groups of the VDX 6740
1
Trunk Group 1 - 1/10 GbE BaseT ports 1-16
4
Trunk Group 4 - 1/10 GbE BaseT ports 41-48
2
Trunk Group 2 - 1/10 GbE BaseT ports 17-32
5
Trunk Group 3A - 40 GbE QSFP ports 49-50
3
Trunk Group 3 - 1/10 GbE BaseT ports 33-40
6
Trunk Group 4A - 40 GbE QSFP ports 51-52
Figure 38. Port Groups of the VDX 6740T and Brocade VDX 6740T-1G
Note: On the Brocade VDX 6740, ports in groups 3 and 3A, as well as port
groups 4 and 4A, can be trunked together only when the 40 GbE QSFP
ports are configured in breakout mode. On the Brocade VDX
6740T/6740T-1G model, this trunking is not allowed.
For more information about Brocade trunking, refer to the Brocade
Network OS Administrator’s Guide, v4.1.0
You can use the fabric isl enable, fabric trunk enable, no fabric isl enable,
and no fabric trunk enable to toggle the ports which are part of a trunked
ISL, if needed. The following example shows the running configuration of
an ISL port on RB21-
BRCD6740-21# show running-config interface FortyGigabitEthernet
21/0/49
interface FortyGigabitEthernet 21/0/49
fabric isl enable
fabric trunk enable
no shutdown
!
You can also verify ISL configurations using the show fabric isl or show
fabric trunk commands on RB21, as shown: